User Manual
Table Of Contents
DSP-RX(-EX) Owner’s Manual
20
Control I/O characteristics
Dimensions (WxHxD), weight
480 mm × 220 mm × 491 mm
DSP-RX-EX: 20 kg, DSP-RX: 19 kg
Accessories
Owner’s Manual, AC power cord × 2, Euroblock plug (three-pin)
Optional items
Mini-YGDAI card, HY card, DEK-DSP-RX (DSP Expansion Kit)
EIA rack mount size
5 U
NC value
15 (Fan Spd: LOW) / 20 (Fan Spd: HIGH)
Measuring position: 100 cm away from the unit’s front panel
Terminal Format Level Connector
Balanced /
Unbalanced
MIDI IN MIDI – DIN 5pin –
OUT MIDI – DIN 5pin –
TC IN SMPTE
SMPTE
0.3 Vpp (Min.) /
10.0 Vpp (Max.), 10 kΩ
XLR-3-31 type
*1
*1. 1= GND, 2= HOT, 3= COLD
Balanced
WORD CLOCK IN – TTL/75 Ω terminated BNC –
OUT – TTL/75 Ω BNC –
GPI – – D-sub (25-pin, female)
*2
*2. Inputs
CH 1-7: TTL logic (input voltage: 0-5 V)
CH 8: Optocoupler (input voltage: 0-24 V / Low level ≤1 V, High level: ≥5 V)
Outputs
CH 1-7: Open-drain (Max. external supply voltage= 12 V, Max. sink current per pin= 75 mA)
CH 8: Relay Contact (Max. 1 A/30 V DC)
Power Supply Pins (5 V ±5%, Max. total output current= 600 mA)
–
REMOTE – RS422 / 232C
*3
*3. Toggled by the switch.
D-sub (9-pin, male) –
FAULT OUTPUT NO – < DC 30 V, < 1 A Euroblock Connector 3P –
C
*4
*4. The C terminal normally short-circuits with the NC terminal, but it short-circuits with the NO terminal in the event that a fault is detected.
–– –
NC – < DC 30 V, < 1 A –
CONSOLE NETWORK IN/OUT – 1000BASE-T etherCON CAT5e
*5
*7
*5. CAT5e or higher cables are recommended for connection.
–
NETWORK IEEE802.3 10BASE-T/100BASE-TX etherCON CAT5
*6
*7
*6. CAT5 or higher cables are recommended for connection.
*7. STP cables are recommended for connection.
–
NETWORK [PC] IEEE802.3 10BASE-T/100BASE-TX etherCON CAT5
*6 *7
–