User Manual

CONTENTS
Part names & functions
32 RIVAGE PM StageMix User Guide
4 KEY IN level meter
Indicates the KEY IN level. A triangle icon indicates the threshold level for the KEY IN filter. If the KEY IN source is paired channels, the
meter will indicate the higher level between L and R.
5 THRESHOLD slider
Specifies the dynamics threshold.
6 Graph
Displays the input/output frequency response.
7 GR meter
Indicates the amount of dynamics gain reduction.
8 Dynamics parameter sliders
Indicate the dynamics parameter values. The type of parameters will vary depending on the currently-selected dynamics processor type.
LEGACY COMP, COMP260, or EXPANDER:
RATIO, ATTACK, RELEASE, OUTGAIN, KNEE
GATE or DUCKING:
RANGE, ATTACK, HOLD, DECAY
DE-ESSER:
FREQUENCY, TYPE, Q
9 INPUT level meter/OUTPUT level meter
Display the peak level for the front and rear stages respectively of the dynamics processor.
) KEY IN SOURCE display
Indicates the currently-selected KEY IN SOURCE.
If DE-ESSER has been selected, it will be fixed to SELF POST EQ.
! KEY IN EDIT button
Tap this button to display the KEY IN FILTER edit screen.
Filter type buttons
Tap these buttons to switch to HPF, BPF, or LPF. Tapping the illuminated button will turn off the corresponding filter type.
FREQUENCY slider
Appears when one of the filter types is turned on. Use this slider to set the filter frequency.
Q slider
Appears when BPF is turned on. Use this slider to set the filter Q.
CUE button
Tap this button to switch cue on or off. If you close the DYN screen, the cue will automatically turned off.
Source indicator