Part names & functions
32 RIVAGE PM StageMix User Guide
4 KEY IN level meter
Indicates the KEY IN level. A triangle icon indicates the threshold level for the KEY IN filter. If the KEY IN source is paired channels, the
meter will indicate the higher level between L and R.
5 THRESHOLD slider
Specifies the dynamics threshold.
6 Graph
Displays the input/output frequency response.
7 GR meter
Indicates the amount of dynamics gain reduction.
8 Dynamics parameter sliders
Indicate the dynamics parameter values. The type of parameters will vary depending on the currently-selected dynamics processor type.
LEGACY COMP, COMP260, or EXPANDER:
RATIO, ATTACK, RELEASE, OUTGAIN, KNEE
GATE or DUCKING:
RANGE, ATTACK, HOLD, DECAY
DE-ESSER:
FREQUENCY, TYPE, Q
9 INPUT level meter/OUTPUT level meter
Display the peak level for the front and rear stages respectively of the dynamics processor.
) KEY IN SOURCE display
Indicates the currently-selected KEY IN SOURCE.
If DE-ESSER has been selected, it will be fixed to SELF POST EQ.
! KEY IN EDIT button
Tap this button to display the KEY IN FILTER edit screen.
• Filter type buttons
Tap these buttons to switch to HPF, BPF, or LPF. Tapping the illuminated button will turn off the corresponding filter type.
• FREQUENCY slider
Appears when one of the filter types is turned on. Use this slider to set the filter frequency.
• Q slider
Appears when BPF is turned on. Use this slider to set the filter Q.
• CUE button
Tap this button to switch cue on or off. If you close the DYN screen, the cue will automatically turned off.
• Source indicator
Indicates the currently-specified KEY IN SOURCE. Tap this area to open the Source select screen.