I/O RACK RPio622 Owner’s Manual AUDIO INTERFACE EN
The above warning is located on the rear of the unit. L’avertissement ci-dessus est situé sur l’arrière de l’unité. Explanation of Graphical Symbols Explication des symboles The lightning flash with arrowhead symbol within an equilateral triangle is intended to alert the user to the presence of uninsulated “dangerous voltage” within the product’s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons.
FCC INFORMATION (U.S.A.) 1. IMPORTANT NOTICE: DO NOT MODIFY THIS UNIT! This product, when installed as indicated in the instructions contained in this manual, meets FCC requirements. Modifications not expressly approved by Yamaha may void your authority, granted by the FCC, to use the product. 2. IMPORTANT: When connecting this product to accessories and/ or another product use only high quality shielded cables. Cable/s supplied with this product MUST be used. Follow all installation instructions.
PA_en_6 1/2 PRECAUTIONS PLEASE READ CAREFULLY BEFORE PROCEEDING Please keep this manual in a safe place for future reference. WARNING Always follow the basic precautions listed below to avoid the possibility of serious injury or even death from electrical shock, short-circuiting, damages, fire or other hazards.
PA_en_6 2/2 Inadequate ventilation can result in overheating, possibly causing damage to the device(s), or even fire. Make sure that there is adequate space around the device: at least 20 cm above, 10 cm at the sides. • Do not place the device in a location where it may come into contact with corrosive gases or salt air. Doing so may result in malfunction. • Avoid being near the device during a disaster, such as an earthquake.
Contents Introduction.............................................................7 Main Features ......................................................................7 Accessories...........................................................................7 Firmware Updates ................................................................7 Precautions for Rack Mounting.............................................7 Recessed Installation ............................................................
Introduction Thank you for purchasing the Yamaha RPio622 I/O rack. The RPio622 is an audio interface that enables you to flexibly configure and expand I/Os for the RIVAGE PM10 system as required by your application or the scale of your system. In order to take full advantage of the RPio622’s superior functionality and enjoy years of trouble-free use, please read this manual before you begin using the product.
Part Names & Functions Front Panel 12 3 4 8 9 5 6 7 This figure illustrates the rack with various RY cards already installed. 1 Color Indicator Indicates the status of the unit. Red (flashing) A critical error has occurred. Yellow (lit steadily) Indicates a minor issue, but you can continue using the unit. Green Normal Refer to the Message List (page 17) for more information on errors.
FaultOut Specifies the conditions under which an alert for abnormality is transmitted from the FAULT OUTPUT connector. Red: An alert is transmitted if an error occurs that causes the color indicator to flash red. Y&R: An alert is transmitted if an error occurs that causes the color indicator to light up yellow steadily or flash red. F/W Ver. Indicates the current firmware version number of the unit. Initialz Initializes the unit. 4 [U]/[D] keys Enable you to select a setting parameter or value.
Rear Panel ! @ # ) $ % ^ ) AC IN connectors Use these sockets to connect the supplied power cords. First connect the AC power cords to this unit, and then insert the power cord plugs into AC outlets. Insert the cord plugs all the way until they lock in place securely. The supplied AC power cords feature a Vlock mechanism via a latch, which prevents the power cords from disconnecting accidentally. NOTE Be sure to connect the power cords to power supply units A and B.
@ FAULT OUTPUT connectors This Euroblock connector is used to abnormal status information to the outside of the unit. Connect a lamp or buzzer here. The NC and C terminals will short-circuit if the unit is operating normally. The NO and C terminals will short-circuit if an abnormality is detected. NOTE The NO and C terminals will also short-circuit if you intentionally turn off the power to the unit, just as they will if a problem with power occurs.
Installing a Euroblock plug 2. Insert the cables. You must use the supplied Euroblock plug to connect to the FAULT OUTPUT connector. NO C NC Preparation (Cable preparation) Approx. 7 mm Approx. 20 mm • Use strand wires for the Euroblock plug. First, strip the strand wire insulation as shown below. After the strand wires are connected to the Euroblock plug, the wires may break due to metal fatigue caused by the weight of the cable or vibration.
Installing and Removing Optional Cards 3. Align both edges of the card with the guide rails inside the slot, and then insert the card into the slot. Push the card all the way into the slot so that the connector at the end of the card is correctly inserted into the connector inside the slot. Installing an RY Card 1. Make sure that both power indicators are off. Caution Installing or removing a card while the power is on may lead to component failure or electric shock. 2.
Removing the RY Card 1. 3. Make sure that both power indicators are off. Caution Installing or removing a card while the power is on may lead to component failure or electric shock. 2. Completely loosen the screws that hold the card in place. 3. Pull the card toward you while holding the screws on the card. 4. Replace the stored slot cover and affix it with the screws. Align both edges of the card with the guide rails inside the slot, and then insert the card into the slot.
Installing an HY Card 1. 4. Make sure that both power indicators are off. Caution NOTE Installing or removing a card while the power is on may lead to component failure or electric shock. 2. Pull up the card installation lever to lock in the card. Make sure that the lever claw is securely locked under the bottom part of the slot. If the lever claw does not lock in, pull up the card slightly, then push it in. Remove the screws that fasten the slot cover to remove the slot cover.
Power Supply Connecting the AC Power Cord 1. Turn off both power switches A and B on the unit. 2. Connect one of the supplied power cords to AC IN connector (A), and the other to AC IN connector (B). 3. Connect the other end of each power cord to an AC outlet of a different power source. NOTE • To disconnect the power cords, remove the cables in the order of steps 1➝3➝2 in the procedure described above. • To disconnect the power cord, remove it while pressing the latch on the plug.
Message List An error message for caution or attention will be displayed on the front panel LCD, and will be indicated via the color indicator. Error messages indicating caution Repair might be required. Contact your Yamaha dealer. LCD Messages Color Indicator Status M1[ERR R0*] H/W ERROR RY SLOT* Red (flashing) A card inserted in the RY card slot is not accessible. An asterisk mark (*) indicates the slot number in relation with the corresponding error.
Specifications General Specifications Sampling frequency Conditions External Clock Internal clock Frequency Range Fs= 44.1 kHz, 48 kHz, 88.2 kHz, 96 kHz Jitter of PLL*1 WORD CLOCK IN Fs= 44.1 kHz, 48 kHz, 88.2 kHz, 96 kHz Frequency Word clock : int 44.1 kHz Word clock : int 48 kHz Word clock : int 88.2 kHz Word clock : int 96 kHz Accuracy *2 Typ Max. Unit –1000 — +1000 ppm — — 10 ns — 44.1 48 88.2 96 — kHz –50 — +50 ppm — — 4.5 4.1 2.3 2.1 ns Min. Typ Max.
Dimensions (WxHxD), weight 480 mm x 455 mm x 490 mm (including the rubber feet), 29 kg Accessories Owner’s Manual (this document), AC power cords (x2), Euroblock plug (three-pin) Optional items RY card, HY card, Mini-YGDAI card Information for Users on Collection and Disposal of Old Equipment This symbol on the products, packaging, and/ or accompanying documents means that used electrical and electronic products should not be mixed with general household waste.
Dimensions 490 13 450 350 65 15 440 455 480 50 350 Unit: mm Approximate Munsell value of exterior color: N5 20 RPio622 Owner’s Manual
Software Licenses and Copyrights This product incorporates the following third party software. For information (copyright, etc.) about each software, please read the terms and conditions stated below. By using this product, you will be deemed to have accepted the terms and conditions. expat Copyright (c) 1998, 1999, 2000 Thai Open Source Software Center Ltd and Clark Cooper Copyright (c) 2001, 2002, 2003 Expat maintainers.
Index B O Brightns (Brightness) ........................................8 C Card Installing HY card.................................................15 MY card ................................................14 RY card .................................................13 Installing/Removing..................................13 Removing HY card.................................................15 MY card ................................................14 RY card .................................................
For details of products, please contact your nearest Yamaha representative or the authorized distributor listed below. Pour plus de détails sur les produits, veuillez-vous adresser à Yamaha ou au distributeur le plus proche de vous figurant dans la liste suivante. NORTH AMERICA CANADA Yamaha Canada Music Ltd. 135 Milner Avenue, Toronto, Ontario, M1S 3R1, Canada Tel: +1-416-298-1311 U.S.A. Yamaha Corporation of America 6600 Orangethorpe Avenue, Buena Park, CA 90620, U.S.A.
Yamaha Pro Audio global website: http://www.yamahaproaudio.com/ Yamaha Downloads http://download.yamaha.