Status Indicator Display
If the LED mode is [LINK/ACT]
The status indicators show each port’s link status and
connection status.
If the LED mode is [STATUS]
The status indicators show the loop-related port’s status.
If the LED mode is [VLAN]
The status indicators show the VLAN ID and trunk.
If DIP switch 1 is upward ([DANTE]), VLAN 1 is shown by
the upper indicator and the lower indicator unlit. VLAN 2
is shown by the upper indicator lit green and the lower
indicator unlit. Trunk is shown by upper and lower
indicators lit orange.
–: Unlit, G: Lit green, O: Lit orange
NOTE
If a number of VLANs that cannot be completely displayed
above is specified, the upper and lower indicators are lit
green.
If multiple VLAN IDs are specified for the same port, the
upper and lower indicators are lit orange.
If the LED mode is [OFF]
All status indicators are unlit.
SWP2 Initialization
Settings can be reinitialized to factory default settings by
the following three methods.
CAUTION
Do not switch off the SWP2 during initialization. Doing so
could cause a product failure.
NOTICE
Settings cannot be reinitialized if the administrative
password is still the default setting. Use Web GUI or
command operations to change the administrative
password.
All communications are temporarily disabled immediately
after reinitialization.
NOTE
The Web GUI can also be used to export current settings
before they are reinitialized. For more details, refer to
“Technical Data.”
If reinitialization fails, have the unit inspected by the dealer
that sold the unit or by contacting the Yamaha customer
service support center.
Using the Web GUI to restore
factory settings
1. Log in to the Web GUI via the Yamaha LAN
Monitor.
2. Click the [Management] tab
[Maintenance] [Restart and initialize], in
that order.
The “Restart and initialize” screen is displayed.
3. In the “Initialize” section, click the [Next]
button.
The “Initialize” screen is displayed.
4. Enter the administrative password and
then click the [OK] button.
The “Check executed content” screen is
displayed.
5. Check the settings and then click the
[Execute] button.
The settings are restored to factory settings and
the SWP2 unit is restarted.
Indicator Illumination Status
Upper
Lit green Link is established. (LINK)
Flashing
green
Data is being transferred.
(ACT)
Unlit Link is lost.
Lower
Lit green
Connected with 1000BASE-T
or 10GBASE-SR/LR.
Lit orange Connected with 100BASE-TX.
Unlit Connected with 10BASE-T.
Indicator Illumination Status
Upper
and lower
Flashing
orange
Loop was detected and
communication was halted, or
an abnormality in the
opticalCON light reception
level was detected.
Unlit
Loop not detected. Or loop
was detected, but
communication is not halted.
Indicators
1
VLAN ID low high
Trunk
Upper GO GO O
Lower G O O G O