User Manual

Table Of Contents
[Initial value]
firmware-update timeout 300
[Input mode]
global configuration mode
[Description]
Specifies the timeout duration when downloading firmware from a web server.
If this command is executed with the "no" syntax, the setting returns to the default.
[Example]
Set the firmware download timeout duration to 120 seconds.
SWP2(config)#firmware-update timeout 120
SWP2(config)#
4.26.5 Allow revision-down
[Syntax]
firmware-update
revision-down enable
no firmware-update revision-down
[Initial value]
no firmware-update revision-down
[Input mode]
global configuration mode
[Description]
When using a firmware file from a web server to update the firmware, this allows the firmware to be changed to a revision that
is older than the current revision.
If this is executed with the "no" syntax, revision-down is not allowed.
[Example]
Allow revision-down.
SWP2(config)#firmware-update revision-down enable
SWP2(config)#
4.26.6 Show firmware update function settings
[Syntax]
show firmware-update
[Input mode]
priviledged EXEC mode
[Description]
Shows the current settings of the firmware update function.
The following items are shown.
Download source URL
Proxy server URL
Download timeout duration
Allow revision-down
Firmware revision on next boot
Reboot time after update
[Example]
Show the current settings of the firmware update function.
SWP2#show firmware-update
url: http://www.rtpro.yamaha.co.jp/firmware/revision-up/swp2.bin
http-proxy: -
timeout: 300 (seconds)
revision-down: Disable
firmware revision for next boot: -
122 | Command Reference | Maintenance and operation functions