User Manual

Table Of Contents
[Initial value]
set timer msg-fast-tx 1
[Input mode]
LLDP agent mode
[Description]
Sets the LLDP frame transmission interval during the high speed transmission period.
If this command is executed with the "no" syntax, the setting returns to the default.
The high speed transmission period is the period immediately after a port's connected device was newly found, and LLDP
frames are transmitted according to the following commands for making high speed transmission period settings.
set timerx msg-fast-tx fast_tx : Sets the transmission interval (seconds) during the high speed transmission period.
set tx-fast-init value : Sets the number of LLDP frames transmitted during the high speed transmission period.
[Example]
Set 2 seconds as the LLDP frame transmission interval during the high speed transmission period on LAN port #1.
SWR2310(config)#lldp run
SWR2310(config)#interface port1.1
SWR2310(config-if)#lldp-agent
SWR2310(lldp-agent)#set timer msg-fast-tx 2
4.22.14 Set time from LLDP frame transmission stop until re-initialization
[Syntax]
set timer reinit-delay reinit_delay
no set timer reinit-delay
[Parameter]
reinit_delay : <1-10>
Time from LLDP frame transmission stop until re-initialization (seconds)
[Initial value]
set timer reinit-delay 2
[Input mode]
LLDP agent mode
[Description]
Sets the time from when LLDP frame transmission stops until re-initialization occurs.
If this command is executed with the "no" syntax, the setting returns to the default.
[Example]
Set 10 seconds as the time from when LLDP frame transmission stops on LAN port #1 until re-initialization occurs.
SWR2310(config)#lldp run
SWR2310(config)#interface port1.1
SWR2310(config-if)#lldp-agent
SWR2310(lldp-agent)#set timer reinit-delay 10
4.22.15 Set multiplier for calculating time to live (TTL) of device information
[Syntax]
set msg-tx-hold value
no set msg-tx-hold
[Parameter]
value : <1-100>
Multiplier for calculating the time to live (TTL) value of device information
[Initial value]
set msg-tx-hold 4
Command Reference | Maintenance and operation functions | 107