User Manual

[Note]
For a LAN/SFP port that was put in the errdisable state by the BPDU guard function before this command was executed, the
change in the setting is applied the next time BPDU is detected.
[Example]
Enable automatic recovery after BPDU guard has caused the errdisable state, and set the recovery time to 600 seconds.
SWR2311P(config)#errdisable auto-recovery bpduguard interval 600
Disable automatic recovery after loop detection has caused the errdisable state.
SWR2311P(config)#no errdisable auto-recovery loop-detect
5.5.2 Show error detection function information
[Syntax]
show errdisable
[Input mode]
unprivileged EXEC mode, priviledged EXEC mode
[Description]
Shows information for the error detection function.
The following items are shown.
Whether automatic recovery from the errdisable state is enabled or disabled
The interface that is in the errdisable state, and the function that detected the error
[Example]
Show information for the error detection function.
SWR2311P>show errdisable
function auto recovery interval
-----------------------------------------------
BPDU guard disable
Loop detect enable 300
Port-security disable
port reason
----------------------------
port1.1 BPDU guard
port1.7 Loop detect
5.6 PoE
5.6.1 Set PoE power supply function (system)
[Syntax]
power-inline switch
no power-inline
[Parameter]
switch : System-wide PoE power supply function settings
Setting value Description
enable
Enables the system-wide PoE power supply
function
disable
Disables the system-wide PoE power supply
function
[Initial value]
power-inline enable
[Input mode]
global configuration mode
164 | Command Reference | Interface control