User Manual

[Example]
Show time synchronization settings. *If the synchronization update interval is one hour
SWR2311P#show ntpdate
NTP Server 1 : ntp.nict.jp
NTP Server 2 : none
adjust time : Thu Jan 1 09:00:00 2015 + interval 1 hour
sync server : ntp.nict.jp
Show time synchronization settings. *If periodic synchronization is not being performed
SWR2311P#show ntpdate
NTP Server 1 : ntp.nict.jp
NTP Server 2 : none
adjust time : Thu Jan 1 09:00:00 2015
sync server : ntp.nict.jp
4.7 Terminal settings
4.7.1 Move to line mode (console terminal)
[Syntax]
line con port
[Parameter]
port : 0
Serial console port number
[Initial value]
line con 0
[Input mode]
global configuration mode
[Description]
Moves to line mode in order to make console terminal settings.
[Note]
To return from line mode to global configuration mode, use the exit command. To return to priviledged EXEC mode, use the
end command.
[Example]
Move to line mode in order to make console terminal settings.
SWR2311P(config)#line con 0
SWR2311P(config-line)#
4.7.2 Set VTY port and move to line mode (VTY port)
[Syntax]
line vty port1 [port2]
no line vty port1 [port2]
[Parameter]
port1 : <0-7>
VTY port number
port2 : <0-7>
Last VTY port number when specifying a range
[Initial value]
no line vty 0 7
[Input mode]
global configuration mode
Command Reference | Maintenance and operation functions | 45