User Manual
[Example]
Enable the RMON alarm group settings with the following conditions.
• The MIB object to be monitored is etherStatsPkts.1.
•
The sampling interval is 180 seconds.
• The sampling type is delta.
• The upper threshold value is 3000, and the event when rising above the upper threshold value is 1.
• The lower threshold value is 2000, and the event when falling below the lower threshold value is 1.
SWR2311P(config)#rmon alarm 1 etherStatsPkts.1 interval 180 delta rising-threshold
3000 event 1 falling-threshold 2000 event 1
4.11.6 Show RMON function status
[Syntax]
show rmon
[Input mode]
unprivileged EXEC mode, priviledged EXEC mode
[Description]
Shows the settings and status of the RMON function.
The following items are shown.
• System-wide RMON function settings
•
RMON function settings for each group
• Ethernet statistical information group
• History group
• Alarm group
• Event group
[Example]
SWR2311P>show rmon
rmon: Enable
statistics:
rmon collection index 1
stats->ifindex = 5001
input packets 7, bytes 600, drop events 0, multicast packets 4
output packets 17, bytes 2091, multicast packets 17 broadcast packets 0
history:
history index = 1
data source ifindex = 5001
buckets requested = 50
buckets granted = 50
Interval = 1800
Owner RMON_SNMP
event:
event Index = 1
Description RMON_SNMP
Event type Log
Event community name RMON_SNMP
Last Time Sent = 00:00:58
Owner RMON_SNMP
alarm:
alarm Index = 1
alarm status = VALID
alarm Interval = 15
alarm Type is Absolute
alarm Value = 0
alarm Rising Threshold = 10
alarm Rising Event = 1
alarm Falling Threshold = 7
alarm Falling Event = 1
alarm Startup Alarm = 3
alarm Owner is RMON_SNMP