User Manual

English
Initialization
SWR2311P-10G Owner’s Manual
35
Entering the <I> (uppercase I) key during startup to restore the factory
settings
The unit can be restored to its factory settings by entering an uppercase <I> when the unit is
starting up. This explanation uses the method of disconnecting and reconnecting the power
cord. The procedure is also the same when using the reload command to restart this unit.
Notice
Here we assume that you are logged in as described in “Logging in from a computer connected to
the CONSOLE port” (page 28).
1. Disconnect and then reconnect the power cord of this unit.
2. During restart, enter an uppercase <I> within one second after the BootROM
Ver (see below) appears on the console screen.
3. When a screen asks you whether to execute initialization, press the <y> key
to execute initialization.
Initialization is executed.
SWR2311P BootROM Ver.1.00
Initialize or not ?(y/n)
Ready to Initialize
...............