Service manual

2. Voltage
9
Connect the pocket tester (DC 20 V) to the
meter assembly coupler (wire harness side)
as shown.
Positive tester probe
brown
11
Negative tester probe
ground
9
Set the main switch to “ON”.
9
Measure the voltage (DC 12 V) of brown
lead terminal
1
on the meter assembly cou-
pler (wire harness side).
9
Is the voltage within specification?
Br L
Dg
GB
Ch Dg
B
Br
Ch
L
G
1
ELEC
8-39
SIGNALING SYSTEM
YES NO
Check the wiring
connections of the
entire signaling sys-
tem
YES NO
Replace the fuel
level gauge.
3. Fuel level gauge
9
Set the main switch to “ON”.
9
Move the float up
1
or down
2
.
9
Check that the fuel level gauge needle
moves to “F” or “E”.
NOTE:
Before reading the fuel level gauge, leave the
float in one position (either up or down) for at
least three minutes.
9
Does the fuel level gauge needle move
appropriately?
1
2
4. Wiring
Check the entire signaling system’s wiring.
http://mototh.com