User Manual

Toolbar
Reference Manual
TF series
-
37
-
A Channel display area
The following information is displayed when the console's Quick Config button is turned
on and a Tio1608-D with the [QUICK CONFIG] switch turned on is connected.
CH Name
CH Color
+48V setting for each channel (the indicator below and to the left of the channel icon
lights in red when turned on)
Information about the DZR-D series and DXS-XLF-D series
B Device information
Touch "Device " on the list item name to sort the device information.
Touch the Version button to switch between the LIMIT/SIGNAL indicator and the
version information.
Padlock icon
This icon is displayed when Dante Device Lock on the DZR-D series and DXS-XLF-D
series is enabled.
Device information
Icons indicating the DZR-D series and DXS-XLF-D series, as well as the unit ID, product
name and Dante device name are shown.
Alert icon
This icon is displayed when an error occurs on the DZR-D series and DXS-XLF-D series.
LIMIT indicator
This indicator lights when the limiter on the DZR-D series and DXS-XLF-D series is active.
SIGNAL indicator
This indicator lights in response to the output level of the DZR-D series and DXS-XLF-D
series.
Version display (switch using button)
Displays the version of the DZR-D and DXS-XLF-D series firmware, as well as the Dante
firmware contained in the DZR-D series and the DXS-XLF-D series.
Identify button
Helps you identify the DZR-D Series and DXS-XLF-D series that is connected. While you
hold down this button, the backlight on the corresponding DZR-D series and DXS-XLF-
D series flashes.
C Output information
Displays information for the TF output channels that are outputted to the DZR-D series
and DXS-XLF-D series.
Touch the "Output" list item name to sort by TF output channel (in order of AUX
MTRX ST SUB MONITOR).
D Mute buttons
Switches the mute function ON/OFF for the DZR-D series and DXS-XLF-D series systems.
If the connected DZR version is V1.1.1 or earlier, then Mute buttons are not displayed.
NOTE
The information below (B C) is not displayed when Quick Config or "with OUTPUT" is disabled.
ռսվ
NOTE
The Identify button displays when Quick Config is enabled.