User Manual

R Remote Version 4.1 Users Guide 35
Update operation
This section describes how to update the firmware.
1.
Start R Remote. Choose “Tool” “Firmware Update” from the menu of R Remote.
2.
(In the case of RMio64-D) Quit the NUAGE Workgroup Manager it it is running.
3.
Press the “Select” button and select the firmware xxxx_v*_**_rrmt.bin” to be updated.
Devices that can be updated appear in the device information area.
Firmware files can be downloaded from the following website:
http://www.yamahaproaudio.com/
xxxx represents the product name and *_** represents the firmware version number.
(E.g. rio3224-d_v4_10_rrmt.bin)
When you select an old firmware which is not supported by R Remote, “invalid file” appears and
the update cannot be started.
If the firmware of the device is an older version than the firmware file, the checkbox for its device
will be automatically checked.
If the firmware of the device is a newer version or a same version, you will need to check the
checkbox of the firmware to update manually.
4.
Press the “Update” button to start the update.
5.
When the update is complete, a popup window appears. Press the "OK" button.
6.
To enable the new firmware, turn the updated device off and then on again.
If updated correctly, “Update Status” on the R Remote Firmware Updater will change from “Finished” to
“Completed.”
Detecting the device
If you select the firmware file, all detected devices on the network that correspond to the file are displayed on
the Device information area. Also, until the update is actually started, new detected devices corresponding to
the file are added to the list as needed. Conversely, when a device is missing or disconnected due to the
cable having been unplugged or some other reason, a “disconnected” indication is shown on the Firmware
Version column of the device.
In case of failure in updating the firmware
Even if the update has failed, you can update the firmware again after R Remote detects the device. However,
when a device is turned off while the update is in progress, the device cannot be started up, and it will not be
shown on the Device information area of the R Remote, making it necessary to take the following actions for
each problem.
When the device name is shown in red on the network grid view of the Dante Controller
Dante firmware has entered failsafe mode. Use Failsafe Recovery function of Dante Firmware Update
Manager. The Dante Firmware Update Manager is compressed together with R Remote.
For details on recovering, refer to the Dante Firmware Update Manager User Guide which is
compressed together with R Remote.
After Failsafe Recovery, try to update the firmware again with R Remote.
When the device’s red indicators light or flash
The firmware of the device is damaged. Use R Remote Recovery Updater to update the firmware.
Details on updating are as given below.