User Manual

R Remote Version 4.1 Users Guide 8
START UP MODE
If a CL/QL series unit is not connected, we recommend that you set START UP MODE to RESUME. If this is
set to REFRESH, settings must be transmitted from the R Remote each time the R series unit is restarted.
For devices other than the RMio64-D and the RSio64-D
Settings
REFRESH
The following settings are initialized when turned the device on.
HA GAIN (-6 dB)
+48V (OFF)
HPF (OFF)
HPF FREQ (80Hz)
Gain Compensation (OFF)
To use the device after initialization, you need to: turn the
device off set the DIP switches to RESUME turn the device on.
(7 and 8 up)
RESUME
(The unit starts up using the settings assigned prior to the most recent
power off.)
RSio64-D
Settings
Switch
NORMAL
(Start up normally with the settings of the previous start-up.)
(7 and 8 up)
INITIALIZE
The following settings are initialized when the device is turned on.
SLOT 1-4 SRC (OFF)
WORD CLOCK SELECT (DANTE/48kHz)
USER PATTERN (same routing configuration as the preset PATTERN # 1)
Static IP (Manual) (0.0.0.0)
PANEL LOCK (Unlock)
Dante PATCH (All OFF)
Dante DEVICE LABEL (Y001-Yamaha-RSio64-D-123456) (*1)
To use the device after initialization, you need to: turn the
device off set the DIP switches to NORMAL turn the device on.
(7 down, 8 up)
(*1) The third and fourth characters of the Dante DEVICE LABEL depend on the device settings of DIP switch 1 and the
SETUP [UNIT ID] rotary switch. The lower six digits depend on the lower six digits of the unit’s MAC address.
Connect the computer and the devices
Use an Ethernet cable to connect the computer and the devices.
If you selected DAISY CHAIN in “SECONDARY PORT” on the above, connect the Dante connectors of the
devices in a daisy chain to the computer.
If you selected REDUNDANT in “SECONDARY PORT” on the above, connect the computer to the network
switch that is connected to the Dante [PRIMARY] connector.