User Manual
Table Of Contents
- Notice regarding data copyright
- Notice regarding the content of this user guide
- Contents
- Chapter 1. An overview of MTX-MRX Editor
- An audio system control network
- Terms used in this user guide
- Data handled by MTX-MRX Editor
- Connection requirements for an MTX/MRX system
- MTX/MRX system configuration examples
- What are YDIF connections? (Cascade mode and Distribution mode)
- What are Dante connections? (Daisy-chain connection and Star connection)
- Patching
- Workflow
- About the screens
- Moving between screens
- Chapter 2. Menu bar and tool buttons
- Chapter 3. Project screen
- Chapter 4. System screen
- Chapter 5. Online and Synchronization
- Chapter 6. Presets
- Chapter 7. Dialog boxes/Software applications
- “Startup” dialog box
- “Network Setup” dialog box
- “Device Information” dialog box
- “Match Device by IP Address” dialog box
- “MTX Configuration” dialog box
- “Dante Information” dialog box
- “Word Clock” dialog box
- “Clock” dialog box
- “Daylight Saving Time” dialog box
- “Scheduler” dialog box
- “Remote Control” dialog box
- “External Events” dialog box
- “Digital Control Panel” dialog box
- “Wireless DCP” dialog box
- “MCP1” dialog box
- “PIN Setup” dialog box
- “Label” dialog box
- “Re-size Image” dialog box
- “PGM1/PGX1” dialog box
- “PGM1 Label Creator” application
- “GPI” dialog box
- “GPI Calibration” dialog box
- “Security Settings” dialog box
- “Project Information” dialog box
- “Configuration Diagram” dialog box
- “Get Log” dialog box
- “Sampling Rate Converter” dialog box
- “Input Source/Redundant” dialog box
- Appendix
“Digital Control Panel” dialog box Chapter 7. Dialog boxes/Software applications
MTX-MRX Editor User Guide
204
• [LED Brightness] box
Specifies the brightness of the DCP unit’s LEDs. Higher values will make the LEDs
brighter.
• [Enable Inactive Mode] check box
If the check box is selected, the unit automatically enters inactive mode after a time
duration specified in [Waiting Time].
[Inactive LED Brightness] specifies the brightness of the LEDs when inactive.
If the check box is cleared, the drop-down menu is grayed-out and you will be unable
to set the brightness.
• [Panel Lock] check box
If this check box is selected, the DCP panel will be locked when the preset library is
recalled.
If the [Enable Temporary Unlocking] check box is selected, pressing and holding
down DCP switch 1 for two seconds will unlock the panel.
•[Waiting Time]
Specifies the time from the last operation until the unit enters inactive mode or the
panel is locked.
● Menu button ( )
Click this button to execute the following functions.
•[Copy]
Copies the Parameter Assign, Dimmer & Lock, and Source Select of the displayed
DCP to the copy buffer.
•[Paste]
Overwrites the Parameter Assign, Dimmer & Lock, and Source Select settings of the
same model from the copy buffer onto the displayed DCP.
It is only possible to paste settings that were copied within the same MTX/MRX
system.
• [Initialize]
Initializes the Parameter Assign, Dimmer & Lock, and Source Select settings of the
displayed DCP.
• [Clear [Parameter Assign]]
Initializes the Parameter Assign settings of the displayed DCP.
● [Close] button
Closes the dialog box.