User Manual
Table Of Contents
- 0. Revision History
- 1. Setup
- 2. Command List
- 3. Command Specifications
- 4. Command Sequence
- 5. Meter Value
- 6. Parameter Value Details
- 6.1. Fader parameter
- 6.2. Other parameters (MTX3, MTX5-D)
- 6.3. Other parameters (MRX7-D)
- 7. Parameter List
- 8. Meter List
MTX3/MTX5-D/MRX7-D/XMV Series/EXi8/EXo8 Remote Control Protocol Specications V3.3.1 rev13
32
3. Command Specications
2-18) Stop request
MTX3,MTX5-D,XMV,EXi8,EXo8
Command Option 1 Description
mtrstop MTX:mtr_MemNo/UniqueId/meter Requests that the specied meter data be stopped.
Details: MemNo = See section 8, "Meter List."
UniqueId = See section 8, "Meter List."
Response
Response string Description
OK mtrstop MTX:mtr_MemNo/UniqueId/meter Meter data stop setting complete
Details: MemNo = See section 8, "Meter List."
UniqueId = See section 8, "Meter List."
Example: Command: mtrstop MTX:mtr_512/20020/meter
Notication: OK mtrstop MTX:mtr_512/20020/meter
Meaning: Stop the meter data of ch1 to 8 output levels.
The request to stop the meter data of ch1 to 8 output levels was received.
MRX7-D
Command Option 1 Option 3 Description
mtrstop MTX:Index_IndexNo level Requests that the specied level meter data be stopped
gr Requests that the specied Gain Reduction meter data be
stopped
hold Requests that the specied hold meter data be stopped
Details: IndexNo = Index number assigned in Remote Control Setup List
Response
Response string Description
OK mtrstop MTX:Index_IndexNo level Level meter data stop setting complete
OK mtrstop MTX:Index_IndexNo gr Gain Reduction meter data stop setting complete
OK mtrstop MTX:Index_IndexNo hold Hold meter data stop setting complete
Details: IndexNo = Index number assigned in Remote Control Setup List
Example: Command: mtrstop MTX:Index_2 level
Notication: OK mtrstop MTX:Index_2 level
(V2.02 or earlier OK mtrstop MTX:Index_002 level)
Meaning: Stop the meter data of ch1 to 8 which are assigned to Index 2 in Remote Control Setup List.
The request to stop the meter data of ch1 to 8 which are assigned to Index 2 in Remote Control
Setup List was received.