User Manual
Table Of Contents
- 0. Revision History
- 1. Setup
- 2. Command List
- 3. Command Specifications
- 4. Command Sequence
- 5. Meter Value
- 6. Parameter Value Details
- 6.1. Fader parameter
- 6.2. Other parameters (MTX3, MTX5-D)
- 6.3. Other parameters (MRX7-D)
- 7. Parameter List
- 8. Meter List
MTX3/MTX5-D/MRX7-D/XMV Series/EXi8/EXo8 Remote Control Protocol Specications V3.1.0 rev10
26
3. Command Specications
3.3.5. Parameter setting
2-13) Raw value parameter setting
MTX3,MTX5-D,XMV,EXi8,EXo8
Command Option 1 Option 2 Option 3 Option 4 Description
set MTX:mem_MemNo/UniqueId/ElmNo/
Xpos/Ypos/PrmNo/IndexNo
0 0 (value) Raw value parameter
setting
Details: MemNo = See section 7, "Parameter List."
UniqueId = See section 7, "Parameter List."
ElmNo = See section 7, "Parameter List."
Xpos = See section 7, "Parameter List."
Ypos = See section 7, "Parameter List."
PrmNo = See section 7, "Parameter List."
IndexNo = See section 7, "Parameter List."
(value) = See section 3.1, "Basic Command Specications," or section 7, "Parameter List."
Response
Response string Description
OK set MTX:mem_MemNo/UniqueId/ElmNo/Xpos/Ypos/
PrmNo/IndexNo 0 0 (value) "(string)"
Raw value parameter setting response
OKm set MTX:mem_MemNo/UniqueId/ElmNo/Xpos/Ypos/
PrmNo/IndexNo 0 0 (value) "(string)"
* If the requested parameter value is outside the range, the value is adjusted within the range and set.
If this occurs, the result notication will be OKm instead of OK.
Details: MemNo = See section 7, "Parameter List."
UniqueId = See section 7, "Parameter List."
ElmNo = See section 7, "Parameter List."
Xpos = See section 7, "Parameter List."
Ypos = See section 7, "Parameter List."
PrmNo = See section 7, "Parameter List."
IndexNo = See section 7, "Parameter List."
(value) = See section 3.1, "Basic Command Specications," or section 7, "Parameter List."
"(string)" = See section 3.1, "Basic Command Specications," or section 7, "Parameter List."
Example: Command: set MTX:mem_512/60000/0/0/0/0/0 0 0 -7760
Response: OK set MTX:mem_512/60000/0/0/0/0/0 0 0 -7760 "-77.60"
Meaning: Set the 1ch level of the DCA fader to a raw value of -77.60.
The 1ch level of the DCA fader was set to "-77.60".
MRX7-D
Command Option 1 Option 2 Option 3 Option 4 Description
set MTX:Index_IndexNo 0 0 (value) Raw value parameter
setting
Details: IndexNo = Index number assigned in Remote Control Setup List
(value) = See section 3.1, "Basic Command Specications," or section 7, "Parameter List."
Response
Response string Description
OK set MTX:Index_IndexNo 0 0 (value) "(string)" Raw value parameter setting response
OKm set MTX:Index_IndexNo 0 0 (value) "(string)"
* If the requested parameter value is outside the range, the value is adjusted within the range and set.
If this occurs, the resulting notication will be Okm instead of OK.
Details: IndexNo = Index number assigned in Remote Control Setup List
(value) = See section 3.1, "Basic Command Specications," or section 7, "Parameter List."
"(string)" = See section 3.1, "Basic Command Specications," or section 7, "Parameter List."
Example: Command: set MTX:Index_1 0 0 -7760
Response: OK set MTX:Index_1 0 0 -7760 "-77.60"
(V2.02 or earlier OK set MTX:Index_001 0 0 -7760 "-77.60")
Meaning: Set the parameter assigned to Index 1 in Remote Control Setup List to -77.60 using raw values.
Level of a parameter which is assigned to Index 1 in Remote Control Setup List was set to "-77.60".