7-25
6. Field coil resistance
S Connect the pocket tester ( 1) to the rotor
as shown.
Field coil resistance
2.8 X 3.0 at 20_C
S Measure the field coil resistance.
S Is the field coil OK?
YES
Replace the field coil.
NO
EAS00749
S Check the mian switch for continuity.
Refer to “CHECKING THE SWITCHES”.
S Is the main switch OK?
YES
Replace the main
switch.
NO
7. Main switch
EAS00779
S Check the wiring connections of the entire
charging system.
Refer to “CIRCUIT DIAGRAM”.
S Is the charging system’s wiring properly con-
nected and without defects?
NO
Replace the rectifier.
YES
8. Wiring
Properly connect or
repair the charging
system’s wiring.
CHARGING SYSTEM
ELEC
EAS00778