Rear panel
1
[AC IN]
Connect the included power cord. When connecting
to a power outlet, first connect the power cord to the
unit, then connect the power cord to the power
outlet.
2
Cooling vent
The Tio1608-D2 contains a cooling fan. The cooling
air is exhausted here, so please be careful not to block
this vent. The air is taken in through the ventilation
ports at the front.
3
[FAN]
Allows you to set the unit's internal cooling fan to run
at high or low speed. The switch is set at the factory
to [LOW], but as long as the unit is operated within
the specified ambient temperature range either the
[LOW] or [HIGH] setting can be used. The [HIGH]
setting is recommended if the ambient temperature is
high, if the unit is in direct sunlight (even if the
ambient temperature is within the specified operating
range), and in any situation in which fan noise is not a
problem. When mounting three or more units without
leaving space between each unit, set each unit's fan
speed to HIGH.
You can change the switch position while the unit is
turned on.
4
DIP switches
Determines the unit's start up mode.
Make sure that the unit is turned off before adjusting
the DIP switches. If you adjust the switches while the
unit is turned on, the new switch positions are not
applied.
The following information explains how the DIP
switch positions.
Switches 1 and 2 (unit ID)
These DIP switches, along with the [UNIT ID],
determine the unit's UNIT ID when Quick Config is not
used.
The UNIT ID is determined as follows.
When Quick Config is used, these switches are
disabled.
Switch 3 (initialize mode)
This DIP switch is used to reset the unit to its factory
default settings.
After the unit is reset, it starts up using the system
mode that corresponds to the position of switches 7
and 8.
ձղճ յնշմ
CAUTION
Make sure the unit is turned off before connecting or
disconnecting the power cord.
CAUTION
Do not block the ventilation ports (heat dissipating slits) on this
product. This product has ventilation ports at the front/rear/sides
to prevent the internal temperature from becoming too high. If
the ventilation ports are blocked, heat will get trapped inside the
product, which may cause malfunction or fire.
Switch
position
[UNIT ID]
= 1
[UNIT ID]
= 2
[UNIT ID]
= 3
01 02 03
04 05 06
07 08 09
0A 0B 0C
Switch
position
Initialize mode
Initialize mode is off (unit will not be reset
when it is turned on)
Initialize mode is on (unit will be reset
when it is turned on)
1 2
1 2
1
2
1
2
3
3