User Manual

How to read the indicators
-
17
-
Owner’s Manual
Tio1608-D2
English
How to read the indicators
You can use the [S
YSTEM] and [SYNC] to confirm the unit's status.
The indicators can relay operational status, error status, and warnings.
Error status
If one of the following errors has occurred, the device will not operate. Until the error is resolved, the green [SYSTEM] will be
turned off, and all indicators for all I/O channels will continue to flash.
In addition, certain errors will cause the red [SYSTEM] to light or flash.
The following errors affect the settings or the hardware. However, the device will still be usable. The green [SYSTEM] will
light, and
all indicators for all I/O channels will work normally.
In addition, certain errors will cause the red [SYSTEM] to light or flash.
[SYSTEM] Description Possible Solution
Off Flashes 2 times
Internal Dante error has occurred. The unit is malfunctioning. Please contact
your nearest Yamaha representative.
Off Flashes 3 times
MAC address setting is damaged and Dante
communication is not possible.
Off Lit
Duplicate UNIT ID was found. Make sure each UNIT ID is only used once
on the Dante network.
[SYSTEM] Description Possible Solution
Lit Flashing
The number of Dante transmit flows
exceeded the limit.
Reduce the number of flows by, for example,
using Dante Controller to change some of the
transmit flows to multicast.
Lit Flashes 2 times
Error occurred when communicating with the
head amp.
Turn the unit off and then on again. If this does
not resolve the problem, please contact your
nearest Yamaha representative.
Lit Flashes 3 times
Internal memory has been corrupted. If using RESUME mode, turn the unit off and
then on again. If this does not resolve the
problem, please contact your nearest
Yamaha epresentative.
Lit Lit
Yo u changed the positions of the device
setting DIP switches, or changed the Dante
settings from Dante Controller. Therefore, the
positions of the device setting DIP switches
do not match the actual Dante settings.
If the Device Lock setting was enabled from
Dante Controller, disable the setting, or
check the device setting DIP switch
positions, and set them to accommodate the
current situation.