Up to eight XP, XM, or XH series units can be connected to the ACD1 via the [MONITOR/REMOTE] connectors.
Connection procedure
1. Connect the ACD1’s [MONITOR/REMOTE] connector to the [MONITOR/REMOTE] connector of the XP,
XM, or XH series unit using a D-Sub 15-pin cable (such as a commercially-available VGA cable for a com-
puter monitor) as shown below.
Use a D-sub straight cable that has all fifteen pins connected.
The maximum D-sub cable length that can be used is 50 meters.
An Ethernet-compatible controller such as AMX or Crestron can be connected, allowing remote control of the ACD1 and the
amplifiers connected to the ACD1.
If you connect an Ethernet-compatible remote controller, you must set the ACD1 IP Port number by using [6.Network Setup]
[IP Ctrl Port #] on the ACD1 unit. Alternatively, in Amp Editor you can click the [Device Setup] menu command [IP Control
Port No.] and open the “IP Control Port No.” dialog box, and then specify the ACD1’s IP port number in the “External Device
Port” field. For details of the remote control communication protocol, please refer to the TXn/ACD1 remote control protocol
specification provided on the website.