User Manual

Appendix
Amp Editor Owner’s Manual
214
Can’t monitor or control
amplifiers from Amp
Editor.
Amp Editor is offline. In the main panel window, click the [OFFLINE] button to switch
it to [ONLINE].
The device is registered as an
“Unmatched Device” in the Tree
View window.
Drag the icon of the device you want to monitor and control,
and drop it in the workspace.
The Device ID or IP address
are not set correctly.
Refer to the device’s owners manual, and perform the setup
again.
The Tn/PC-N series amplifier
connected to the ACD1 does
not have the correct terminator
setting.
Set the T switch located on the rear panel of the last amplifier
(in the chain of amplifiers connected to the [DATA PORT] con-
nector) to the ON position.
Set the T switch of other amplifiers to the OFF position.
The connected amplifiers were
started before the ACD1.
Turn on the power to the ACD1 first, then to the amplifiers con-
nected to the ACD1.
All scene data saved in
the device has disap-
peared.
The power was turned off while
the devices data was being
saved.
Synchronize with Amp Editor once again to transmit the set-
tings.
Symptom Possible causes Response
Manual Development Group
© 2009 Yamaha Corporation
Published 06/2017 PO-E0