“Log Setup” dialog box
In the “Event Log” dialog box, click the [Log Setup] button to access the “Log Setup” dialog box. Here you can
automatically obtain an event log from a device and save it as a file, or manually obtain and save an event log.
Click the [OK] button to apply the modified settings and close the dialog box.
[Log file setup] tab
[Enable logging] check box
Turns on/off the function that automatically writes the obtained event log to a file. If this is checked, the obtained
event log will be written to a file in the specified folder at the following timing.
• When you quit Amp Editor
• When midnight occurs while Amp Editor is running
• When the number of obtained log events exceeds 2,560.
Even if this check box is cleared, the event log will still be saved in the device itself; however when the capacity
of the device itself is exceeded, the old log events will be overwritten by newer log events.