Owner`s manual

– 27 –
0°C
å
YAMALUBE 4 (10W-40)
SAE 10W
ç
SAE #20
SAE #30
32°F
25°C
80°F
Engine oil replacement
Avoid draining the engine oil immediately after
stopping the engine. The oil is hot and should be
handled with care to avoid burns.
1. Place the generator on a level surface and warm
up the engine for several minutes. Then stop the
engine.
2. Remove the oil filler cap.
3. Place an oil pan under the engine. Remove the oil
drain bolt so that the oil can be completely
drained.
4. Check the oil drain bolt, gasket, oil filler cap and
O-ring.
If damaged, replace.
1 Oil filler cap
2 O-ring
3 Oil drain bolt
4 Gasket
5. Install the oil drain bolt.
6. Add engine oil to the upper level.
1 Upper level
WARNING
Drain bolt torque:
30 Nm (3.0 m·kgf, 22 ft·lbf)
Recommended engine oil:
å YAMALUBE 4 (10W-40),
SAE 10W-30 or 10W-40
SAE #30
ç SAE #20
SAE 10W
Recommended engine oil grade:
API Service SE type or higher
Engine oil quantity:
1.1 L (1.16 US qt, 0.97 Imp qt)
7DA-F8199-12-B 2011.2.21 13:11 Page 27