Owner`s manual

– 37 –
6. Drain the fuel remaining in the carburetor into an
approved container by loosening the drain screw
on the carburetor float chamber.
1 Drain screw
7. Tighten the drain screw.
8. Turn the engine switch to “STOP”.
9. Turn the fuel cock lever to “OFF”.
10. Tighten further if any screws, bolts and nuts are
loose.
11. Store the generator in a dry, well-ventilated place,
with the cover placed over it.
Engine
Perform the following steps to protect the cylinder, pis-
ton ring, etc. from corrosion.
1. Remove the spark plug, pour about one table-
spoon of SAE 10W-30 or 20W-40 motor oil into
the spark plug hole and install the spark plug only.
Recoil start the engine by turning over several
times (with ignition off) to coat the cylinder walls
with oil.
2. Pull the recoil starter until you feel compression.
Then stop pulling. (This prevents the cylinder and
valves from rusting).
3. Clean exterior of the generator and apply a rust
inhibitor.
4. Store the generator in a dry, well-ventilated place,
with the cover placed over it.
5. The generator must remain in a vertical position
when stored, carried or operated.