Specifications

E.g.) ACK if the connection status of the amp with AMP ID 0 on the ACD1 is successfully obtained:
GCON OK
CON 0 ON
ACK if unsuccessful in obtaining an amp connection status:
GCON ERR
3.3.7. Fault Out Control Comman
d
26) SFO: Used to set/reset Fault Out
Comman
d
Optio
n
SFO 0 [Fault Out Set/Reset (ON/OFF)] SFO OK SFO ERROR
The command name stands for "Set Fault Out".
This command only applies to TXn firmware V1.30, ACD1 firmware V1.12, or later.
This command will enable the user to set/reset the Fault Out status on the TXn/ACD1 from the controller.
- The first option is always 0.
- [Fault Out Set/Reset] should be a character string of either "ON" when setting or "OFF" when resetting.
- A space will be needed between the command and the option, and between the options.
E.g.) To reset the Fault Out status:
SFO 0 OFF
- The TXn/ACD1 will return a one-line character string of "SFO OK" if successful.
- The TXn/ACD1 will return a one-line character string of "SFO ERR" if unsuccessful.
E.g.) ACK if the Fault Out status is successfully reset:
SFO OK
3.3.8. Identify Control Comman
d
27) SIDENT: Used to switch Identify on/of
f
28) GIDENT: Used to obtain Identify on/of
f
Comman
d
Optio
n
SIDENT 0 [Identify ON/OFF] SIDENT OK SIDENT ERR
IDENT 0 [Identify ON/OFF
]
GIDENT 0 GIDENT OK GIDENT ERR
IDENT 0 [Identify ON/OFF
]
The command names stand for "Set Identify" and "Get Identify" respectively.
These commands only apply to TXn firmware V1.30, ACD1 firmware V1.12, or later.
These commands will enable the user to set/obtain the Identify On/Off status on the TXn/ACD1 from the controller.
- The first option is always 0.
- [Identify ON/OFF] should be a character string of either "ON" or "OFF".
- A space will be needed between the command and the option, and between the options.
E.g.) To set the Identify to On:
SIDENT 0 ON
To obtain the Identify On/Off:
GIDENT 0
- The TXn/ACD1 will return a two-line character string if successful.
The first line should be a character string "SIDENT OK" or "GIDENT OK".
The second line should be a character string "IDENT 0 [Identify ON/OFF]".
The first line can be ignored for the controller.
- The TXn/ACD1 will return a one-line character string of "SIDENT ERR" or "GIDENT ERR" if unsuccessful.
E.g.) ACK if Identify ON is successfully set:
SIDENT OK
IDENT 0 ON
ACK if unsuccessful in setting Identify On/Off:
SIDENT ERR
ACK if Identify ON/OFF is successfully obtained when the status is ON:
GIDENT OK
IDENT 0 ON
TXn/ACD1's ACKs when unsuccessful
TXn/ACD1's ACKs when unsuccessful
TXn/ACD1's ACKs when successful
TXn/ACD1's ACKs when successful
TXn/ACD1 Remote Control Protocol Specifications V1.12