User Manual

TXn AMP section (Model dependent)
TX4n
Parameter categor
y
Parameter name MI
N
MAX MI
N
MAX MI
N
MAX unit
00 01 / 00 / 00 00 / 00 00 Power Amp Mode Power Amp Mode 0 2 0 2 0 2 0
0
:
St
ereo
1:Bridge
2:Parallel
01 00 Gain Setting Mode Gain Setting Mode 0 1 0 1 0 1 0 0:Link OFF 1:Link O
n
00 01 / 01 /
00:Ch A
01:Ch B(*1) 00 / 00 00 Sensitivity Sensitivity 0 240 -14 226 -21 219 dBu
va
l
ue x
0
.
1[dB
u
]
TX4n:(-2.1 - 21.9[dBu])
TX5n:(-1.4 - 22.6[dBu])
TX6n:(0.0 - 24.0[dBu])
(*4)(*5) ex 11.6[dBu]=116
198(*1) 438(*1) 198(*1) 438(*1) 198(*1) 438(*1) dB
// /
258(*2) 498(*2) 258(*2) 498(*2) 258(*2) 498(*2)
Speaker Output Voltage
-380
(
*1
)
450
(
*1
)
-380
(
*1
)
450
(
*1
)
-380
(
*1
)
450
(
*1
)
dBu
// /
-320(*2) 510(*2) -320(*2) 510(*2) -320(*2) 510(*2)
00
/
01 00 Enable 0 1 0 1 0 1 0 0:Disable 1:Enable
Speaker Output Power
0 4800
(
*1
)
0 4200
(
*1
)
0 3600
(
*1
)
W
/
/
/
0 9600
(
*2
)
0 8400
(
*2
)
0 7200
(
*2
)
00
/
01 00 Enable 0 1 0 1 0 1 0 0:Disable 1:Enable
00 01 / 04 /
00:C
h
A
01:Ch B(*1) 00 / 00 00 Speaker Output Imp Alert Max Threshold 0 2500 0 2500 0 2500 ohms
va
l
ue x 0.1[o
h
ms]
(0.0 - 250.0[ohms]) ex 95.6[ohms]=956
01 00 Alert Min Threshold 0 2500 0 2500 0 2500 ohms
va
l
ue x 0.1[o
h
ms]
(0.0 - 250.0[ohms]) ex 95.6[ohms]=956
02 00 Enable 0 1 0 1 0 1 0 0:Disable 1:Enable
00 01
/
05
/
00 00
/
00 00 Speaker Output Detection Alert Detection Time 1 10 1 10 1 10 s 0
01 00 Alert Coun
t
1 100 1 100 1 100 0 0
Voltage Limite
r
0
(
*1
)
450
(
*1
)
0
(
*1
)
450
(
*1
)
0
(
*1
)
450
(
*1
)
dBu
// /
0(*2) 510(*2) 0(*2) 510(*2) 0(*2) 510(*2)
01 00 Attac
k
1 100 1 100 1 100 ms 0
02 00 Release 1 1000 1 1000 1 1000 s value x 0.01[s] (0.0 - 10.0[s]) ex 1.54[s]=154
03 00
On
010101
0:O
ff
1:On
00 01 / 07 /
00:C
h
A
01:Ch B(*1) 00 / 00 00 Power Limiter
10 4800(*1) 10 4200(*1) 10 3600(*1) W 0
10 9600
(
*2
)
10 8400
(
*2
)
10 7200
(
*2
)
01 00
On
0:O
ff
1:On
00 01
/
08
/
00 00
/
00 00 Limiter Gain Reductio
n
Lin
k
0 1 0 1 0 1 0 0:Off 1:O
n
*1: Power Amp Mode=Stereo or Parallel
*2: Power Amp Mode=Bridge
*3: High Sample Mode Onl
y
*4: Sensitivity and PowerAmpGain operate togethe
r
*5: When Gain Setting Mode=0(Link On), chA and B take same value.
*6: Can be set when Redundant Mode is not "OFF".
*7: Can be set when Redundant Mode = Override
*8: Can be set when Redundant Mode =Overrride and AutoReturn=1
*9: When Redundant Mode=Override/AutoReturn=1/OverrideChannelLink=1, chB cannot be set
Remarks
TX6n TX5n
Parameter informationAccess ID
value x 0.1[dB]
(19.8 - 49.8(*1)/25.8 -
49.8(*2)[dB])
(
*
4)(
*
5)
ex 29.1[dB]=291
00 01 02
00:Ch A
01:Ch B(*1)
00 00 00
Alert Max Threshold value x 0.1[dBu]
(-38.0 - 45.0(*1)/-32.0 -
51.0
(
*2
)
[dBu]
)
ex -5.4[dBu]=-54
00 01 03
00
:
Ch
A
01:Ch B(*1)
00 00 00
Alert Max Threshold 0
00 01 06
00:Ch A
01:Ch B(*1)
00 00 00
Threshold value x 0.1[dBu]
(-38.0 - 45.0(*1)/-32.0 -
51.0
(
*2
)[
dBu
])
ex -5.4[dBu]=-54
Threshold
00 01 00
Power Amp Gain
Appendix - Parameter (TXn Amp)
18