User Manual
Table Of Contents
- Cover
- Contents
- Introduction
- Controls and Connectors
- Panel Operations
- Basic Operations
- Screen Structure
- Operations that can be Performed from the Panel
- Alert Messages
- HOME Screen
- METER Screen
- SETTING Screen
- UTILITY Screen
- MENU Screen
- SIGNAL PATH Screen
- SIGNAL PATH Block Diagrams
- Recalling library settings (Speaker Processor only)
- Slot Input Router
- Input On/Off
- 4x4 Matrix Mixer
- 8Band Input EQ
- Input Delay
- Oscillator Mix
- X-Over Input Level (Speaker Processor)
- X-Over Polarity (Speaker Processor)
- X-Over (Speaker Processor)
- Output Delay (Speaker Processor)
- 6Band Output EQ (Speaker Processor)
- Output Level (Speaker Processor)
- Mute On/Off (Speaker Processor)
- Limiter (Speaker Processor)
- Output Router
- SCENE Screen
- Initializing the internal memory
- System Connection Examples
- Connecting External Controllers and Analog Devices
- Adjusting the Input/Output Levels
- Appendix
TX6n/5n/4n Reference Manual
17
Panel Operations
For each meter type, this screen lets you specify various parameters for alert detection, peak hold, and display
units.
● Setting procedure
1. In the HOME screen, press the left-most function button (METER) to access the METER screen.
2. Use the function buttons (PREV/NEXT) to access the screen for the meter whose settings you want to change.
3. Press the second-from-right function button (SETTING) to access the SETTING screen for that meter.
4. Press the second-from-left function button (CH A/B or CH 1/2) to access the settings for the channel that you
want to edit.
5. Use encoder A to move the cursor to the parameter that you want to edit, and encoder B to edit the parameter
value.
The edited parameter value will be reflected by the amplifier in real time.
SETTING Screen
Channel whose settings you will edit