Double-click the block to display the component editor for it.
Section Parameter Setting Range Function
1 Setting Priority Setting Priority Hardware/
Software
The MY16-C switch settings take priority when
“Hardware” is selected, and the DME Designer
settings take priority when “Software” is
selected.
2 Bundle Number Input 0 to 65279 Sets the input bundle number.
Output 0 to 65279 Sets the output bundle number.
3 Serial Channel Rx OFF, 1 - 16 Sets the serial channel for the receive side.
Tx OFF, 1 - 16 Sets the serial channel for the send side.
4 Properties Bit Length Bit Off
16 bit
20 bit
24 bit
Sets the bit rate for output. Mutes the signal if
[Bit Off] is set.
5 Latency 5.33 ms
2.67 ms
1.33 ms
Sets the delay.
NOTE
The parameters will not link immediately when Setting Priority is switched.
Please edit another parameter after switching Setting Priority.