manual

M7CL Owner’s Manual
Installing the MBM7CL meter bridge (option)
300
1. Remove screw A from the rear of the M7CLs touch screen, and remove the connector cover.
2. Remove screws B (two locations).
3. Loosen screws C (two locations) so that they protrude approximately 2 mm.
4. Hook holes D of the MBM7CLs attachment fixture over the M7CLs screws C (two locations, at left and
right).
5. Connect the MBM7CLs connector E to the M7CLs connector F.
* Orient the connector so that the red cable is at the right when viewed from the rear panel.
6. Insert the two screws B (which you removed in step 2) into holes G of the MBM7CLs attachment fix-
ture, and tighten them.
7. Tighten screws C (two locations) to fasten the MBM7CL to the M7CL.
8. Using screw A which you removed in step 1, fasten the cable cover included with the MBM7CL. This
completes the installation procedure.
Installing the MBM7CL meter bridge (option)
C
A
C
B
B
2 mm
2 mm
M7CL main unit
Connector cover
B
G
G
D
D
C
C
E
A
B
F
MBM7CL
Red cable
Cable cover
Shown as completed
Before connecting the MBM7CL meter bridge to the M7CL, you must turn off the power switches of the
M7CL and the PW800W. Failure to observe this will cause malfunctions or electric shock.