User Manual

VXL1-16P Remote Control Protocol Specications Version 1.0.0 rev1
14
3. Command Specications
2-12) Stop request
VXL1-16P
Command Option 1 Description
mtrstop MeterId Requests that the specied meter data be stopped.
Details: MeterId = See section 8, "Meter List."
Response
Response string Description
OK mtrstop MeterId Meter data stop setting complete
Details: MeterId = See section 8, "Meter List."
Example: Command: mtrstop AMP:DigitalIn/Level
Response: OK mtrstop AMP:DigitalIn/Level
Meaning: Stop the meter data of ch1 to 2 output levels.
The request to stop the meter data of ch1 to 2 output levels was received.
3.4. Extended commands
3.4.1. Product information query request
3-1) VXL1-16P external control protocol version query
Command Option 1 Description
devinfo protocolver Queries the MTX external control protocol version
Response
Response string Description
OK devinfo protocolver "xxxx" VXL1-16P external control protocol version
Details: xxxx = Version
Example: Command: devinfo protocolver
Notication: OK devinfo protocolver "1.0.0"
Meaning: Query the protocol version.
Protocol version = V1.0.0
3-2) Parameter set version query
Command Option 1 Description
devinfo paramsetver Queries the parameter set version
Response
Response string Description
OK devinfo paramsetver "xxxx" Parameter set version
Details: xxxx = Version
Example: Command: devinfo paramsetver
Notication: OK devinfo paramsetver "AMP:1.0.0 VXL:1.0.0"
Meaning: Query the parameter set version.
Parameter set version ="AMP:1.0.0 VXL:1.0.0"