VXL1-16P Remote Control Protocol Specications Version 1.0.0 rev1
21
4. Command Sequence
Applying the most recent status of the controller to the device
Remote controller Controlled device
Synced Synced
OK set VXL:Ch/InputVolume/Level 0 0 -775 "-7.75"
set VXL:Ch/InputVolume/Level 0 0 -775
Running normally
Connection detection
Running normally
Communication possible
Apply
OK set XXX/XXXXX/X/X/X/X/X X X XXXX "XXXX"
set XXX/XXXXX/X/X/X/X/X X X XXXX
Apply
OK set XXX/XXXXX/X/X/X/X/X X X XXXX "XXXX"
* Repeat get for all the necessary parameters.
set XXX/XXXXX/X/X/X/X/X X X XXXX
Apply
......
Even when the latest state on the controller side is reected, depending on the situation, the value may be rounded on the operation
target device side.
Therefore, the result notication is reected again on the controller side as necessary.
4.3. Parameter query sequence at any given time
LEDs and displays on the GUI
Indications are updated on the basis of the result notications returned after the processing of the set commands.
Alternatively, send an explicit get request and apply the result to the indications, as shown below.
Remote controller Controlled device
OK get VXL:Ch/InputVolume/Level 0 0 -775
get VXL:Ch/InputVolume/Level 0 0
An event occurs that
calls for a value to be queried
One example of using this sequence would
be for refreshing the UI after boot-up or after
changing tabs.
Apply