VXL1-16P Remote Control Protocol Specications Version 1.2.0 rev2
6
2. Command List
2.1. Commands from a device sent to a remote controller
No. Notication details Reply from device Remarks
1-1 Device status
change notication
Device run mode notication NOTIFY devstatus runmode…
1-2 Device error status notication NOTIFY devstatus error…
1-3 Parameter change
notication
Parameter change notication raw value NOTIFY set…
Parameter change notication normalized value NOTIFY setn…
1-4 Meter information
notication
Meter information notication NOTIFY mtr…
1-5 Event processing
change notication
Device identify notication NOTIFY set AMP:Identied…
1-6 Alert notication NOTIFY event AMP:Alert…
1-7 IP address assignment (DHCP/Auto IP or Static IP)
change notication
NOTIFY event VXL:SetIpSettingPcMode
1-8 IP address change notication NOTIFY event VXL:SetNextBootIpAddress
1-9 Subnet Mask change notication NOTIFY event
VXL:SetNextBootSubnetAddress
1-10 Default Gateway change notication NOTIFY event
VXL:SetNextBootDefaultGateway
2.2. Commands for controlling a device
No. Notication details Reply from device Remarks
2-1 Device status query Device run mode query devstatus runmode
2-2 Device error status query devstatus error
2-3 VXL1-16P external
control protocol run
mode setting
Result and change notication character encoding
setting
scpmode encoding…
2-4 Value notication mode setting scpmode valuetype…
2-5 Normalization resolution setting scpmode resolution…
2-6 Keep alive activation setting scpmode keepalive…
2-7 Parameter query Raw value parameter query get…
2-8 Normalized value parameter query getn…
2-9 Parameter setting Raw value parameter setting set…
2-10 Normalized value parameter setting (*) setn…
2-11 Meter control Transmission request mtrstart…
2-12 Stop request mtrstop…
* When value is set "1023" (default:1000), control resolution becomes same as "Raw value" command.
See "6.1. Fader parameter" for the "Nomalised value" vs "Raw value" when the value is set "1023"
2.3. Extended commands
No. Notication details Reply from device Remarks
3-1 Product information
query request
VXL1-16P external control protocol version query devinfo protocolver…
3-2 Parameter set version query devinfo paramsetver…
3-3 Firmware version query devinfo version…
3-4 Product name query devinfo productname…
3-5 Serial number query devinfo serialno…
3-6 Device ID query devinfo deviceid…
3-7 Product manufacture name query devinfo manufacturer…
3-8 Device name query event AMP:IdentifyDev…
3-9 DIP switch 6 (IP SETTING) status query event VXL:GetIpSetting
3-10
IP address assignment (DHCP/Auto IP or Static IP) setting
when the DIP switch 6 (IP SETTING) is set to "PC"
event VXL:SetIpSettingPcMode
3-11
IP address assignment (DHCP/Auto IP or Static IP) query
when the DIP switch 6 (IP SETTING) is set to "PC"
event VXL:GetIpSettingPcMode
3-12 IP address setting (Static IP address setting) when
the DIP switch 6 (IP SETTING) is set to "PC"
event VXL:SetNextBootIpAddress
3-13 IP address query after the next boot event VXL:GetNextBootIpAddress
3-14 Subnet Mask setting when the DIP switch 6
(IP SETTING) is set to "PC"
event VXL:SetNextBootSubnetAddress
3-15 Subnet Mask query after the next boot event VXL:GetNextBootSubnetAddress
3-16 Default Gateway setting when the DIP switch 6
(IP SETTING) is set to "PC"
event VXL:SetNextBootDefaultGateway
3-17 Default Gateway query after the next boot event VXL:GetNextBootDefaultGateway