User Manual

10
VXL1B-16P/VXL1W-16P Owner’s Manual
Controls and Connectors
DIP switch 5
Not used. Leave this at the factory setting (upward).
DIP switch 6 (IP SETTING)
Specifies how the IP address used for communication with external
devices is set.
DIP switch
Setting
UNIT ID
Content
The IP address is specified by the UNIT ID as
“192.168.0.(UNIT ID).”
DIP switch
Setting
PC
Content
If a DHCP server exists, the IP address is specified by
the DHCP server. If a DHCP server does not exist, the IP
address is specified by the link local address.
NOTE
With the factory settings this is set to UNIT ID.
DIP switches 7 and 8 (START UP MODE)
Specify the startup mode.
DIP switch
Setting
RESUME
Content
The normal operating mode. When the power turns on,
the unit starts up and maintains the state in which it was
immediately prior to power-off.
DIP switch
Setting
INITIALIZE
Content
Initializes the unit, returning it to the factory-set state
(page 14).