User Manual

8
VXL1B-16P/VXL1W-16P Owner’s Manual
Controls and Connectors
Front panel Rear panel
1
4
5
3
2
1
Power indicator
Lit green when power is being supplied correctly. This goes dark
approximately 30 seconds after startup. During initialization, it flashes
rapidly. It flashes when you execute the identification function from a
controlling device.
2
SYNC indicator
Indicates the operating status of the Dante network.
If the green indicator is lit, this indicates that the device is a clock
slave and is synchronized to the clock.
If the green indicator is flashing, this indicates that the device is the
clock master. If the orange indicator is flashing at regular intervals,
the word clock setting within the Dante network is incorrect.
Use Dante Controller to set the clock master and the sampling
frequency correctly.
3
LINK/ACT indicator
Indicates the communication status of the Dante/NETWORK port.
This flashes rapidly if the Ethernet cable is connected correctly.
4
Dante/NETWORK port
An RJ45 port for connection via an Ethernet cable (CAT5e or higher)
to a Dante device such as the MRX7-D, through a PSE (Power
Sourcing Equipment) unit.
•Do not connect this port to anything other than a Dante-enabled
device or a gigabit Ethernet device (including a computer).
•The maximum length of cable that can be used is 100 meters.
•To prevent electromagnetic interference, use STP (Shielded
Twisted Pair) cable.
5
Device settings DIP switches
Specify startup settings for the
device. A label explaining these
settings is affixed to the rear panel.