Service manual

7-20
E
–+
ELEC
STARTING SYSTEM
STARTER SWITCH
1. Check:
Continuity
Out of specification Replace.
Starter continuity
(red coupler)
Lock plate Position
Leads
Red Brown
Installed
Free
Push
Removed
Free
Push
STARTER RELAY
1. Inspect:
Brown lead terminal
Black lead terminal
Loose Tighten.
2. Check:
Starter relay
Faulty Replace.
Checking steps:
Connect the tester leads between the
starter relay terminals as shown.
Connect the brown lead terminal to
the positive battery terminal.
Connect the black lead terminal to the
negative battery terminal.
Check that there is continuity between
the starter relay terminals.
Check that there is no continuity after
the brown or black lead is removed.