Service manual
7-20
E
–+
ELEC
STARTING SYSTEM
STARTER SWITCH
1. Check:
● Continuity
Out of specification → Replace.
Starter continuity
(red coupler)
Lock plate Position
Leads
Red Brown
Installed
Free
Push
Removed
Free
Push
STARTER RELAY
1. Inspect:
● Brown lead terminal
● Black lead terminal
Loose → Tighten.
2. Check:
● Starter relay
Faulty → Replace.
Checking steps:
● Connect the tester leads between the
starter relay terminals as shown.
● Connect the brown lead terminal to
the positive battery terminal.
● Connect the black lead terminal to the
negative battery terminal.
● Check that there is continuity between
the starter relay terminals.
● Check that there is no continuity after
the brown or black lead is removed.