User Manual

CL Editor Owner’s Manual
111
In the Outport Setup window you can assign the source channel for each output port and set the parameters.
The window includes the following items.
1 Output port select tabs
These tabs switch the output ports controlled in the window in groups of up to eight ports.
2 DELAY SCALE field
Here you can select the units for the delay time shown below the delay time knob (8). If the RECORDER tab is
selected for the Output port select tabs (
1), the DELAY SCALE field will be hidden in the screen.
meter (343.59m/s)
The delay time is shown as a distance in meters, calculated as the speed of sound (343.59 m/s) at an air temperature of
20°C (68°F) multiplied by the delay time (seconds.)
feet (1127.26ft/s)
The delay time is shown as a distance in feet, calculated as the speed of sound (1127.26 feet/s) at an air temperature of
20°C (68°F) multiplied by the delay time (seconds.)
•sample
The delay time is shown as a number of samples. If you change the sampling frequency at which the CL operates, the
number of samples will change accordingly.
•ms
The delay time is shown in units of milliseconds.
•frame
The delay time is shown as a frame rate. You can select the frame rate from the following options:
3 Output port
This indicates the type and number of the output port to which the channel is assigned.
4 Channel select
This area lets you select the channel that is assigned to the output port.
30 30 frame/s (Non-drop)
30D 30 frame/s (Drop frame)
29.97 29.97 frame/s (Non-drop)
29.97D 29.97 frame/s (Drop frame)
25 25 frame/s
24 24 frame/s
Outport Setup window
1
2
3
5
6
78
9
0
A
4