User Manual

CL Editor Owner’s Manual
41
If COMPANDER-H, COMPANDER-S is selected
1 TYPE
Indicates the type of the currently selected compander (a combination of compressor and expander.) You can click here
to select the type.
2 LIBRARY
This button accesses the dynamics library. Clicking this button will open the DYNAMICS page of the Library window.
3 ON
This button switches the compander on/off.
4 Response curve
Indicates the response for the compander of the currently selected channel.
5 GR meter (Gain Reduction meter)
This meter indicates the amount of gain reduction produced by the compander.
6 THRESH (Threshold level)
Specifies the threshold level at which compression and expansion are applied. The input signal will be compressed
when the key-in signal exceeds this level. The expander effect will apply to levels below THRESHOLD + WIDTH.
7 RATIO
Specifies the ratio (the amount of compression.)
8 WIDTH
Specifies the width between the threshold level of the compressor (THRESHOLD) and the threshold level of the
expander.
9 ATTACK
Specifies the time (the attack time) until it starts to compress and expand the input signal once the compander has been
triggered.
0 GAIN
Adjusts the gain of the signal after it has passed through the compander.
A RELEASE
Specifies the time (the release time) from when the key-in signal falls below the threshold level until compression and
expansion are removed.
B KEY IN SOURCE
Click this to select the key-in signal that you want to use.
The choices are the same as for GATE.
1
4
B
235
0
7
8
6
9
A