User Manual

CL5/CL3/CL1Firmware Update Guide 13
cable might be disconnected or broken, whether the TCP/IP settings are correct, and whether the CL is running.
8.
Click [Start].
The update operation will begin.
Updating(n/m)” appears in the Status field during updating. “Done” is displayed once update is completed.
Update takes 2 to 4 minutes. During the update operation, do not turn off the power to the unit or disconnect the
cable. If update fails due to disconnection of the power cable during the update, or due to other reasons, the device
may become inoperative.
If update is not completed after 5 minutes, or update failure indication appears, click X at the upper right corner
of Dante Firmware Update Manager to exit the program
without turning the CL power off
, and restart the
procedure from the step 4. If update still fails, follow the instructions stated in “About Failsafe Mode” to perform
the recovery processing.
9.
Restart the CL series.
The firmware update is now complete.