CL5/CL3/CL1Firmware Update Guide 5
power again to resume the initialization.
・ If CL-MD***.BIN (*** indicates the version number) has already been copied into the root directory of the
USB memory at this time, it will be transferred to the NAME SUB CPU firmware update. Refer to "
Updating
the CL NAME SUB CPU Firmware".
・ Similarly, if FWUpdate_CL?_v*****_sw***.dnt (? indicates the product name and *** the version number)
has already been copied into the root directory of the USB memory, it will be transferred to the Dante
firmware update. Refer to "Updating the Dante Firmware
".
10.
When a "Console initialized due to memory mismatch.” popup window (or similar message) appears,
press the CLOSE button to close it.
・Since it is a message about initialization even if displayed as an error, please continue update.
11.
When an "Initialize All Memories ?" message appears, press the INITIALIZE button.
12.
When an "Are you sure ?" message appears, press the OK button.
Initializing the internal memory will be started. When you initialize, SECONDARY PORT settings will be DAISY
CHAIN.
13.
When the initialization is complete, press the EXIT button.
14.
Remove the USB memory after confirming the ACCESS indicator has disappeared in the function
access area.
15.
If necessary, confirm the firmware was correctly updated in the version field in the SETUP screen.