User Manual
Table Of Contents
- Cover
- What is Amp Editor?
- Special Notices
- Contents
- Preparing for operation
- An overview of Amp Editor
- Setup
- Basic operations in Amp Editor
- Main panel window
- Objects in the window and their function
- Menus in the main panel window
- Preferences
- Event Log
- Device Information
- Scene Manager
- Alert Setup
- Word Clock (TXn only)
- Speaker Processor Library Manager (TXn only)
- Clock
- Language (TXn only)
- GPI (ACD1 only)
- Utility
- IP Address
- IP Control Port No.
- Firmware Update (Updating the internal firmware)
- Scene Link Manager (for devices other than XMV)
- Network Setup
- Synchronization (Synchronization with devices)
- Custom Control Panel Manager
- System View Creator
- Speaker Processor Library Converter
- Tree View window
- Detail View window
- Device Properties window
- Signal Path View window (TXn only)
- Component editor (TXn only)
- Custom control panels
- Appendix
Chapter 7 Detail View window
Amp Editor Owner’s Manual
122
General section
Here you can monitor and control overall settings for the entire amplifier.
q Temperature monitor (TXn/Tn/PC-N only)
The meter shows the temperature of the heat sink of the amp section in a range of 0%–100%. If this exceeds
90%, the protection circuit will operate and the speaker output will be muted; please allow sufficient margin
for operation.
• The meter shows only the head sink temperature of the amp section. The temperature of the power
supply section is not shown.
• The temperature at 90% will differ between amplifiers. For details, refer to the owner’s manual or
reference manual of each amplifier.
The power supply protection indicator shows the status of the power supply section, and will turn red if the
amplifier’s power supply protection temperature is exceeded. If an alert has been specified in the “Alert
Setup” dialog box, the alert indicator will also light and be recorded in the log.
The amplifier protection indicator will turn red when the heat sink temperature of each channel of the ampli-
fier exceeds the threshold value specified in the [Output Alert] tab (page 137) of the Device Properties win-
dow. If an alert has been specified in the “Alert Setup” dialog box, the alert indicator will also light and be
recorded in the log.
Power supply protection indicator Alert indicator
Normal state : green
Power supply protection active : red
Normal state : unlit
Power supply protection active : lit
Amplifier protection indicator Alert indicator
Within threshold level : green
Threshold level exceeded : red
Within threshold level : unlit
Threshold level exceeded : lit