User Manual

MTX3/MTX5-D/XMV Series/EXi8/EXo8 Remote Control Protocol Specications V1.0.3
41
4. Command Sequence
Applying the most recent status of the controller to the device
Remote controller Controlled device
Synced Synced
OK set MTX:mem_512/60000/0/0/0/0/0 0 0 -7760 "-77.60"
set MTX:mem_512/60000/0/0/0/0/0 0 0 -7760
Normally running
Connection detection
Normally running
Communication possible
Apply
OK set MTX:mem_XXX/XXXXX/X/X/X/X/X X X XXXX "XXXX"
OK set MTX:mem_XXX/XXXXX/X/X/X/X/X X X XXXX
Apply
OK set MTX:mem_XXX/XXXXX/X/X/X/X/X X X XXXX "XXXX"
* Repeat get for all the necessary parameters.
OK set MTX:mem_XXX/XXXXX/X/X/X/X/X X X XXXX
Apply
......
Depending on the controller specications, the above two sequences may be used in combination.
Example: The GPI fader uses the status of the controller, but other parameters use the status of the controlled device.
Parameter query sequence at any given time
LEDs and displays on the GUI
Indications are updated on the basis of the result notications returned after the processing of the set commands.
Alternatively, send an explicit get request and apply the result to the indications, as shown below.
Remote controller Controlled device
OK get MTX:mem_512/XXXXX/X/X/X/X/X X X
get MTX:mem_512/XXXXX/X/X/X/X/X X X
An event occurs that
calls for a value to be queried
One example of using this sequence would
be for refreshing the UI after boot-up or after
changing tabs.
Apply