MTX3/MTX5-D/MRX7-D/XMV Series/EXi8/EXo8 Remote Control Protocol Specications V3.3.0 rev12
27
3. Command Specications
2-14) Normalized value parameter setting
MTX3,MTX5-D,XMV,EXi8,EXo8
Command Option 1 Option 2 Option 3 Option 4 Description
setn MTX:mem_MemNo/UniqueId/ElmNo/
Xpos/Ypos/PrmNo/IndexNo
0 0 (value) Normalized value
parameter setting
Details: MemNo = See section 7, "Parameter List."
UniqueId = See section 7, "Parameter List."
ElmNo = See section 7, "Parameter List."
Xpos = See section 7, "Parameter List."
Ypos = See section 7, "Parameter List."
PrmNo = See section 7, "Parameter List."
IndexNo = See section 7, "Parameter List."
(value) = See section 3.1, "Basic Command Specications," or section 7, "Parameter List." (*)
* When value is set "1023" (default:1000), control resolution becomes same as "Raw value" command.
See "6.1 Fader parameter " for the "Nomalised value" vs "Raw value" when the value is set "1023"
Response
Response string Description
OK setn MTX:mem_MemNo/UniqueId/ElmNo/Xpos/Ypos/
PrmNo/IndexNo 0 0 (value) "(string)"
Normalized value parameter setting response
OKm setn MTX:mem_MemNo/UniqueId/ElmNo/Xpos/Ypos/
PrmNo/IndexNo 0 0 (value) "(string)"
* If the requested parameter value is outside the range, the value is adjusted within the range and set.
If this occurs, the result notication will be OKm instead of OK.
Details: MemNo = See section 7, "Parameter List."
UniqueId = See section 7, "Parameter List."
ElmNo = See section 7, "Parameter List."
Xpos = See section 7, "Parameter List."
Ypos = See section 7, "Parameter List."
PrmNo = See section 7, "Parameter List."
IndexNo = See section 7, "Parameter List."
(value) = See section 3.1, "Basic Command Specications," or section 7, "Parameter List."
"(string)" = See section 3.1, "Basic Command Specications," or section 7, "Parameter List."
Example: Command: setn MTX:mem_512/60000/0/0/0/0/0 0 0 408
Response: OKm setn MTX:mem_512/60000/0/0/0/0/0 0 0 408 "-20.56"
Meaning: Set the 1ch level of the DCA fader to a normalized value of 408.
The 1ch level of the DCA fader was set to "-20.56".
MRX7-D
Command Option 1 Option 2 Option 3 Option 4 Description
setn MTX:Index_IndexNo 0 0 (value) Normalized value
parameter setting
Details: IndexNo = Index number assigned in Remote Control Setup List
(value) = See section 3.1, "Basic Command Specications," or section 7, "Parameter List."(*)
* When value is set "1023" (default:1000), control resolution becomes same as "Raw value" command.
See "6.1 Fader parameter " for the "Nomalised value" vs "Raw value" when the value is set "1023"
Response
Response string Description
OK setn MTX:Index_IndexNo 0 0 (value) "(string)" Normalized value parameter setting response
OKm setn MTX:Index_IndexNo 0 0 (value) "(string)"
* If the requested parameter value is outside the range, the value is adjusted within the range and set.
If this occurs, the result notication will be OKm instead of OK.
Details: IndexNo = Index number assigned in Remote Control Setup List
(value) = See section 3.1, "Basic Command Specications," or section 7, "Parameter List."
"(string)" = See section 3.1, "Basic Command Specications," or section 7, "Parameter List."
Example: Command: setn MTX:Index_1 0 0 408
Response: OK setn MTX:Index_1 0 0 408 "-21.50"
(V2.02 or earlier OK setn MTX:Index_001 0 0 408 "-21.50")
Meaning: Set a parameter assigned to Index 1 in Remote Control Setup List to 408 using normalized values.
Level of a parameter which is assigned to index 1 in Remote Control Setup List was set to 408 "-21.50".