Chapter 5 Main panel window
Amp Editor Owner’s Manual
75
[Mute]
The muting status of the specified amp will be output from GPI OUT. Use [Device] to select the
amplifier that will be controlled. If you select “ALL,” all amplifiers connected to that device will be
selected.
[Parameter], [Threshold], and [Polarity] are unavailable. [Output Type] specifies how the output from
GPI OUT will occur.
[Standby/On]
The power Standby/On status of the specified amp will be output from GPI OUT. Use [Device] to
select the amplifier that will be controlled. If you select “ALL,” all amplifiers connected to that device
will be selected.
[Parameter], [Threshold], and [Polarity] are unavailable. [Type] specifies how the output from GPI
OUT will occur.
[Parameter Value Edit]
The state of a component’s parameter will be output from GPI OUT. Use [Device] to select the appli-
cable amplifier.
Use [Parameter] to specify the name of the parameter that will be sent from GPI OUT when it is mod-
ified. [Threshold] specifies the threshold value of the parameter. [Output Type] and [Polarity] specify
how the output from GPI OUT will occur.
[Direct Parameter Value]
A signal will be output from GPI OUT when the component’s parameter reaches a specific value. Use
[Device] to select the applicable amplifier.
[Parameter] specifies the name of the parameter. [Threshold] specifies the value of the parameter.
[Polarity] is unavailable. [Output Type] specifies how the output from GPI OUT will occur.
[Alert]
Message indicating that an alert specified by Alert Setup will be output from GPI OUT. [Output Type]
is fixed to .
Output Type Polarity GPI OUT output
cannot be
specified
The output will be Closed when the value specified by [Parameter] is
above [Threshold], and Open when the value is below it.
cannot be
specified
The output will be Closed when the value specified by [Parameter] is
below [Threshold], and Open when the value is above it.
The output will briefly change (for 250 msec) from Open to Closed
when the value specified by [Parameter] changes from below
[Threshold] to above it.
The output will briefly change (for 250 msec) from Open to Closed
when the value specified by [Parameter] changes from above
[Threshold] to below it.
The output will briefly change (for 250 msec) from Closed to Open
when the value specified by [Parameter] changes from below
[Threshold] to above it.
The output will briefly change (for 250 msec) from Closed to Open
when the value specified by [Parameter] changes from above
[Threshold] to below it.