Operation Manual
BASIC SERVICE INFORMATION
1-35
• After disassembling and assembling a cou-
pler, pull on the leads to make sure that they
are installed securely.
4. Connect:
• Lead
• Coupler
• Connector
TIP
• When connecting a coupler or connector,
push both sections of the coupler or connec-
tor together until they are connected
securely.
• Make sure all connections are tight.
5. Check:
•Continuity
(with the pocket tester)
TIP
• If there is no continuity, clean the terminals.
• When checking the wire harness, perform
steps (1) to (3).
• As a quick remedy, use a contact revitalizer
available at most part stores.
6. Check:
• Resistance
1
Pocket tester
90890-03112
Analog pocket tester
YU-03112-C
Pocket tester
90890-03112
Analog pocket tester
YU-03112-C