Operation Manual

ELECTRICAL COMPONENTS
8-133
▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼
a. Connect the pocket tester (DC 20 V) to the
turn signal/hazard relay terminal as shown.
b. Set the main switch to “ON”.
c. Measure the turn signal/hazard relay input
voltage.
▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲
2. Check:
Turn signal/hazard relay output voltage
Out of specification Replace.
▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼
a. Connect the pocket tester (DC 20 V) to the
turn signal/hazard relay terminal as shown.
b. Set the main switch to “ON”.
c. Measure the turn signal/hazard relay out-
put voltage.
▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲
EAS28050
CHECKING THE DIODE
1. Check:
Diode 2
Out of specification Replace.
TIP
The pocket tester or the analog pocket tester
reading are shown in the following table.
▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼
a. Disconnect the diode 2 from the wire har-
ness.
b. Connect the pocket tester (Ω × 1) to the
diode 2 terminals as shown.
Pocket tester
90890-03112
Analog pocket tester
YU-03112-C
Positive tester probe
Blue “1”
Negative tester probe
Ground
Turn signal/hazard relay output
voltage
DC 12 V
Pocket tester
90890-03112
Analog pocket tester
YU-03112-C
Positive tester probe
Brown/white “1”
Negative tester probe
Ground
Pocket tester
90890-03112
Analog pocket tester
YU-03112-C
Continuity
Positive tester probe Blue/
yellow “1”
Negative tester probe Red/
black “2”
No continuity
Positive tester probe Red/
black “2”
Negative tester probe Blue/
yellow “1”