d:09 Fuel system voltage
(battery voltage)
Approximately 12.0 Set the engine stop switch
to “ ”, and then compare
with the actually measured
battery voltage. (If the bat-
tery voltage is lower, per-
form recharging.)
d:20 Sidestand switch Set on/off the sidestand
switch.
Stand retracted ON
Stand extended OFF
d:60 EEPROM fault code display
No history 00
History exists 01 or 02 (Cylinder fault code)
(If both cylinders are defec-
tive, the display alternates
every two seconds.)
d:61 Malfunction history code
display
No history 00
History exists Fault code Nos. 12–50
(If more than one code
number is detected, the dis-
play alternates every two
seconds to show all the
detected code numbers.
When all code numbers are
shown, the display repeats
the same process.)
d:62 Malfunction history code
erasure
No history 00
History exists Displays the total number of
malfunctions, including the
current malfunction, that
have occurred since the his-
tory was last erased. (For
example, if there have been
three malfunctions, “03” is
displayed.)
To erase the history, set the
engine stop switch from “
to “ ”.
d:63 Malfunction code reinstate-
ment (for fault code No. 24)
No malfunction code 00
Malfunction code exists Fault code No. 24 To reinstate, set the engine
stop switch from “ ” to
“”.
d:70 Control number 0–254 [-]
Diag-
nostic
code
No.