User Manual

MTX3/MTX5-D/MRX7-D/XMV Series/EXi8/EXo8 Remote Control Protocol Specications V2.2.0 rev8
17
3. Command Specications
2-3) Current Fs (sampling frequency) status query
Command Option 1 Description
devstatus fs Queries Fs
Response
Response string Description
OK devstatus fs "unknown" Fs undened
OK devstatus fs "44.1kHz" 44.1kHz
OK devstatus fs "48kHz" 48kHz
Example: Command: devstatus fs
Response: OK devstatus fs "44.1kHz"
Meaning: Query Fs.
The current Fs is 44.1 kHz.
2-4) Current word clock status query
Command Option 1 Description
devstatus lockstatus Queries the word clock lock status
Response
Response string Description
OK devstatus lockstatus "unlock" Unlock
OK devstatus lockstatus "lock" Lock
Example: Command: devstatus lockstatus
Response: OK devstatus lockstatus "lock"
Meaning: Query the word clock lock status.
Locked
3.3.2. Device run mode query
2-5) Emergency run mode change
Command Option 1 Description
devmode normal Sets the run mode to normal
emergency Sets the run mode to emergency
Response
Response string Description
OK devmode normal Normal run mode change complete
OK devmode emergency Emergency run mode change complete
Example: Command: devmode emergency
Response: OK devmode emergency
Meaning: Change to emergency mode.
Run mode was changed to emergency.