3. Command Specications
2-18) Stop request
MTX3,MTX5-D,XMV,EXi8,EXo8
Command Option 1 Description
mtrstop MTX:mtr_MemNo/UniqueId/meter Requests that the specied meter data be stopped.
MTX:mtr_MemNo/UniqueId/hold Requests that the specied hold meter data be stopped.
Details: MemNo = See section 7, "Parameter Values."
UniqueId = See section 7, "Parameter Values."
Response
Response string Description
OK mtrstop MTX:mtr_MemNo/UniqueId/meter Meter data stop setting complete
OK mtrstop MTX:mtr_MemNo/UniqueId/hole Hold meter data stop setting complete
Details: MemNo = See section 7, "Parameter Values."
UniqueId = See section 7, "Parameter Values."
Example: Command: mtrstop MTX:mtr_512/20020/meter
Notication: OK mtrstop MTX:mtr_512/20020/meter
Meaning: Stop the meter data of ch1 to 8 output levels.
The request to stop the meter data of ch1 to 8 output levels was received.
MRX7-D
Command Option 1 Option 3 Description
mtrstop MTX:Index_IndexNo level Requests that the specied level meter data be stopped
gr Requests that the specied Gain Reduction meter data be
stopped
hold Requests that the specied hold meter data be stopped
Details: IndexNo = Index number assigned in Remote Control Setup List
Response
Response string Description
OK mtrstop MTX:Index_IndexNo level Level meter data stop setting complete
OK mtrstop MTX:Index_IndexNo gr Gain Reduction meter data stop setting complete
OK mtrstop MTX:Index_IndexNo hold Hold meter data stop setting complete
Details: IndexNo = Index number assigned in Remote Control Setup List
Example: Command: mtrstop MTX:Index_2 level
Notication: OK mtrstop MTX:Index_2 level
(V2.02 or earlier OK mtrstop MTX:Index_002 level)
Meaning: Stop the meter data of ch1 to 8 which are assigned to Index 2 in Remote Control Setup List.
The request to stop the meter data of ch1 to 8 which are assigned to Index 2 in Remote Control