Service manual

8 - 28
+
ELEC
CHARGING SYSTEM
EBS01066
NO
YES
EBS01100
YES
NO
YES
NO
3. Charging voltage
Connect the engine tachometer to on to
the ignition coil.
Connect the pocket tester (DC 20 V) to the
battery as shown.
Positive tester probe
positive battery terminal
1
Negative tester probe
negative battery terminal
2
Start the engine and let it run at approxi-
mately 5,000 r/min.
Measure the charging voltage.
Charging voltage
14 V at 5,000 r/min
NOTE:
_
Make sure the battery is fully charged.
Is the charging voltage within specifica-
tion?
The charging circuit
is OK.
4. Charging coil resistance
Disconnect the A.C. magneto coupler from
the wire harness.
Connect the pocket tester (
×
1) to the
charging coils.
Positive tester probe
white
1
Negative tester probe
ground
2
Measure the charging coil resistance.
Charging coil resistance
0.288 ~ 0.432
at 20 °C (68 °F)
Replace the pickup
coil/stator assembly.
5. Wiring
Check the entire charging systems wiring.
Refer to CIRCUIT DIAGRAM.
Is the charging systems wiring properly
connected and without defects?
Replace the rectifier/
regulator.
Replace the diode
and properly con-
nect or repair the
charging systems
wiring.
WY
1
2
1